DC Balanced Reactor
    Variable Frequency Drive
    DC Flat Wave Reactor
    Input Reactor
    Output Reactor
    Energy Feedback Reactor
    Reactor of PMSM
    Rotor Inverter BOOST Reacto…
    Dv/dt Filter
    Sine Wave Filter
    Passive Harmonic Filter
    LCL Filter
    EMC Filter
    Power Quality
    SVG Reactor
    APF Reactor
    Three Phase Series Detuning…
    Three Phase Series Tuned Re…
    Single-phase series detunin…
    Electric Vehicle
    BOOST Reactor For EV
    PFC Reactor for Charger
    High Frequency Reactor
    High Frequency Transformer
    New Energy
    Wind Power Filter Reactor
    Photovoltaic Filter Reactor…
    Photovoltaic Isolation Tran…
    Transformer
    Rectifier Transformer
    Power Frequency Transformer…
    Energy Consumption Braking
    Braking Unit
    Wirewound Resistor
    Aluminum-enclosure Resistor…
    Braking Resistance Box
    Braking Resistance Cabinet

    Recommendation

    Current position:Home > DC Balanced Reactor > Reactor for Parker DC BUS

    Reactor for Parker DC BUS

    Comment     Time:2018-07-16    Views     Category:DC Balanced Reactor

    Circuitry application: 

              Voltage/Power regulation  of fully controlled rectifier bridge for DC circuits, which can make the output DC current continuity and smooth, also reduce the current impact to the DC motor; This kind of reactor belongs to double-valued reactor, when installed in 12 pulse rectification, it can act as an balanced  reactor, paralleling two sets of dc bus, help to remove the circumfluence between two sets of rectifier bridge.



    • Performance features

      Rated voltage

      DC700V/DC1150V

      Insulation grade 

      F

      Noise

      ≤70dB

     Electric strength

      AC3000V/AC4200V

      Ambient tempereature

      -25~40

      Operative norm

      GB10229-88 reactorIEC2891987 reactorJB9644-1999 reactor for transmission   semiconductor



    Dimensions and technical parameter:


    Insulation grade : F

    Models

    Picture

    Specifications of  Parker

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    PKDL-0030-UISA-500A

    A

    DC485V/30A

    30

    50

    44

    240

    240

    350

    200

    143

    13*26

    PKDL-0060-UISA-250A

    DC485V/60A

    60

    25

    81

    280

    300

    410

    240

    185

    14*28

    PKDL-0090-UISA-175A

    B

    DC485V/90A

    90

    17.5

    115

    320

    250

    500

    200

    190

    14*28

    PKDL-0125-UISA-125A

    DC485V/125A

    125

    12.5

    140

    320

    250

    620

    200

    190

    14*28

    PKDL-0210-UISA-750B

    DC485V/210A

    210

    7.5

    234

    400

    280

    685

    296

    230

    14*28

    PKDL-0280-UISA-550B

    DC485V/280A

    280

    5.5

    270

    440

    305

    710

    336

    230

    14*28

    PKDL-0400-UISA-400B

    DC485V/400A

    400

    4

    327

    480

    345

    750

    376

    230

    14*28

    PKDL-0600-UISA-250B

    DC485V/600A

    600

    2.5

    421

    600

    385

    790

    496

    220

    14*28

    PKDL-0850-UISA-180B

    DC485V/850A

    850

    1.8

    529

    640

    420

    820

    536

    230

    14*28

    PKDL-1200-UISA-125B

    DC485V/1200A

    1200

    1.25

    662

    720

    450

    860

    616

    230

    14*28

    Remarks:Copper DC reactor(type EISC) will be a little heavier, the remaining items are the same