Circuitry application:
Installed at the input side of the explosion-proof inverter PWM rectifier in mining industry, reduce the higher harmonic current caused by the switching frequency ripple current.
Performance features:
Rated voltage |
AC690V/AC1140V,50HZ |
Insulation grade |
H |
Noise |
≤70 d B |
Electricstrength |
AC4200V 50Hz 5s leakage current≤5m A |
Ambient temperature |
-25℃~75℃,explosion-proof |
Operative norm |
GB10229-88 reactor、IEC289:1987 reactor、JB9644-1999 reactor for transmission semiconductor |
Dimensions and technical parameter:
Technical parameter of explosion-proof feedback reactor
Explosion-proof reactor, System voltage: 3-AC690V,50Hz,explosion-proof series frequency converter, Insulation level: H; Ceiling of reactor temperature rise≤70K-80K |
||||||||||||||||
Specifications and models |
Figure No. |
Carrier frequency(KHz) |
Power of frequency converter (kW) |
Rated current(A) |
Inductance (mH) |
Weight (KG) |
Dimensions(mm) |
|||||||||
W |
D |
H |
WO |
DO |
A*B |
|||||||||||
FHCL-0090-EISC-150B |
A |
2 |
75 |
90 |
1.5 |
137.7 |
430 |
260 |
410 |
240 |
210 |
14*28 |
||||
FHCL-0110-EISC-120B |
2 |
90 |
110 |
1.2 |
151.9 |
430 |
270 |
410 |
240 |
220 |
14*28 |
|||||
FHCL-0150-EISC-900C |
2 |
110 |
150 |
0.9 |
189.7 |
430 |
270 |
510 |
240 |
220 |
14*28 |
|||||
FHCL-0200-EISC-700C |
B |
2 |
160 |
200 |
0.7 |
221.9 |
480 |
270 |
540 |
200 |
220 |
14*28 |
||||
FHCL-0250-EISC-550C |
2 |
200 |
250 |
0.55 |
260.8 |
480 |
280 |
660 |
200 |
220 |
14*28 |
|||||
FHCL-0300-EISC-450C |
2 |
250 |
300 |
0.45 |
270.9 |
480 |
305 |
660 |
200 |
220 |
14*28 |
|||||
FHCL-0400-EISC-450C |
1.5 |
355 |
400 |
0.45 |
360.7 |
540 |
350 |
690 |
220 |
240 |
14*28 |
|||||
FHCL-0480-EISC-380C |
1.5 |
450 |
480 |
0.38 |
419.3 |
600 |
360 |
710 |
240 |
240 |
14*28 |
|||||
FHCL-0600-EISC-300C |
1.5 |
560 |
600 |
0.3 |
521.8 |
660 |
390 |
730 |
260 |
250 |
14*28 |
|||||
FHCL-0800-EISC-230C |
1.5 |
710 |
800 |
0.23 |
761.2 |
720 |
470 |
780 |
280 |
310 |
14*28 |
|||||
Explosion-proof reactor, System voltage:3-AC1140V,50Hz,explosion-proof series frequency converter, Insulation level: H; Ceiling of reactor temperature rise≤70K-80K |
||||||||||||||||
Specifications and models |
Figure No. |
Carrier frequency(KHz) |
Power of frequency converter (kW) |
Rated current(A) |
Inductance (mH) |
Weight (KG) |
Dimensions(mm) |
|||||||||
W |
D |
H |
WO |
DO |
A*B |
|||||||||||
FHCL-0150-EISC-160B |
B |
2 |
200 |
150 |
1.6 |
273.6 |
480 |
290 |
660 |
200 |
230 |
14*28 |
||||
FHCL-0200-EISC-120B |
2 |
280 |
200 |
1.2 |
331.3 |
540 |
340 |
690 |
220 |
230 |
14*28 |
|||||
FHCL-0250-EISC-120B |
1.5 |
355 |
250 |
1.2 |
389.2 |
600 |
345 |
710 |
240 |
230 |
14*28 |
|||||
FHCL-0300-EISC-980C |
1.5 |
450 |
300 |
0.98 |
441.0 |
600 |
360 |
710 |
240 |
240 |
14*28 |
|||||
FHCL-0350-EISC-840C |
1.5 |
500 |
350 |
0.84 |
491.8 |
660 |
390 |
730 |
260 |
240 |
14*28 |
|||||
FHCL-0400-EISC-735C |
1.5 |
630 |
400 |
0.735 |
567.5 |
720 |
470 |
780 |
280 |
240 |
14*28 |
|||||
FHCL-0480-EISC-613C |
1.5 |
710 |
480 |
0.613 |
752.0 |
720 |
470 |
780 |
280 |
310 |
14*28 |
Remarks: A/B/C stand for three-phase input side;X/Y/Z stand for output side.