DC Balanced Reactor
    Variable Frequency Drive
    DC Flat Wave Reactor
    Input Reactor
    Output Reactor
    Energy Feedback Reactor
    Reactor of PMSM
    Rotor Inverter BOOST Reacto…
    Dv/dt Filter
    Sine Wave Filter
    Passive Harmonic Filter
    LCL Filter
    EMC Filter
    Power Quality
    SVG Reactor
    APF Reactor
    Three Phase Series Detuning…
    Three Phase Series Tuned Re…
    Single-phase series detunin…
    Electric Vehicle
    BOOST Reactor For EV
    PFC Reactor for Charger
    High Frequency Reactor
    High Frequency Transformer
    New Energy
    Wind Power Filter Reactor
    Photovoltaic Filter Reactor…
    Photovoltaic Isolation Tran…
    Transformer
    Rectifier Transformer
    Power Frequency Transformer…
    Energy Consumption Braking
    Braking Unit
    Wirewound Resistor
    Aluminum-enclosure Resistor…
    Braking Resistance Box
    Braking Resistance Cabinet

    Recommendation

    Current position:Home > Passive Harmonic Filter > Passive Harmonic Filter

    Passive Harmonic Filter

    Comment     Time:2018-07-17    Views     Category:Passive Harmonic Filter

    Circuitry application: 

             At the input side of 6 pulse rectifying installation(frequency converter、DC speed-regulator、the integrated rectifier cabinet at electric vehicle charging stations), it can help to ameliorate distortion rate of current&content of harmonic, improve the power factor of equipment.

    Test effect:

    The following outcomes are comparisons between 15KW inverters  adding and without the passive harmonic filter:


    voltage-current waveform and current distortion THDI without the passive harmonic filter:

    voltage-current waveform and current distortion THDI Adding the passive harmonic filter:


    Performance features:

      Rated voltage

      3-AC400V /690V50HZ

      Insulation grade

      H

      Noise

      ≤70 dB

      Electric strength

      AC3000V/AC4200V  50Hz  5s  leakage current5m A

     Power Factor

      From 0.8 to 0.9

      Current distortion rate

      ≤8%-10%   

      Ambient temperature

      ≤-25~40℃  



    Dimensions and technical parameter:

    Technical parameter of passive harmonic filter

    Applications: 3-AC400V, 50HZ 6 pulse rectifying installation,

    the filter can reduce the current distortion rate of power grid (THDI) from 40% to under 10%

    Models

    Power of frequency converter (kW)

    Current(A)

    Weight(KG)

    Dimensions(mm)

    L

    W

    H

    L0

    WO

    SHF-0005

    2.2

    5

    23

    500

    200

    235

    480

    180

    SHF-0010

    3.7

    10

    29

    500

    200

    235

    480

    180

    SHF-0013

    5.5

    13

    30

    500

    200

    235

    480

    180

    SHF-0016

    7.5

    16

    35

    500

    200

    235

    480

    180

    SHF-0025

    11

    25

    45

    600

    240

    250

    570

    220

    SHF-0030

    15

    30

    50

    600

    240

    250

    570

    220

    SHF-0040

    18.5

    40

    65

    635

    320

    270

    610

    290

    SHF-0045

    22

    45

    70

    635

    320

    270

    610

    290

    SHF-0060

    30

    60

    75

    635

    320

    270

    610

    290

    SHF-0075

    37

    75

    80

    635

    320

    270

    610

    290

    SHF-0090

    45

    90

    90

    680

    350

    275

    650

    320

    SHF-0110

    55

    110

    105

    680

    350

    275

    650

    320

    SHF-0150

    75

    150

    140

    805

    370

    335

    770

    330

    SHF-0180

    90

    180

    160

    805

    370

    335

    770

    330

    SHF-0220

    110

    220

    190

    880

    450

    350

    835

    410

    SHF-0260

    132

    260

    210

    880

    450

    350

    835

    410

    SHF-0320

    160

    320

     

    800

    600

    2000

    Cabinet type

    SHF-0400

    200

    400

     

    800

    600

    2000

    SHF-0480

    250

    480

     

    800

    600

    2000

    Remarks:The initial current distortion rate of above mentioned specifications(THDI) is 40%, if the initial value is higher than this, please enlarge the current gear according to the proportion; Besides, if the voltage of system is 690V, the filter has to be specially  customized.