DC Balanced Reactor
    Variable Frequency Drive
    DC Flat Wave Reactor
    Input Reactor
    Output Reactor
    Energy Feedback Reactor
    Reactor of PMSM
    Rotor Inverter BOOST Reacto…
    Dv/dt Filter
    Sine Wave Filter
    Passive Harmonic Filter
    LCL Filter
    EMC Filter
    Power Quality
    SVG Reactor
    APF Reactor
    Three Phase Series Detuning…
    Three Phase Series Tuned Re…
    Single-phase series detunin…
    Electric Vehicle
    BOOST Reactor For EV
    PFC Reactor for Charger
    High Frequency Reactor
    High Frequency Transformer
    New Energy
    Wind Power Filter Reactor
    Photovoltaic Filter Reactor…
    Photovoltaic Isolation Tran…
    Transformer
    Rectifier Transformer
    Power Frequency Transformer…
    Energy Consumption Braking
    Braking Unit
    Wirewound Resistor
    Aluminum-enclosure Resistor…
    Braking Resistance Box
    Braking Resistance Cabinet

    Recommendation

    Current position:Home > Three Phase Series Detuning Reactor > Series Detuning Reactor

    Series Detuning Reactor

    Comment     Time:2018-07-19    Views     Category:Three Phase Series Detuning Reactor

    Circuitry application:

             There are lots of inductive load from power grid,which create Static Var,  this reactor is in series with shunt capacitor, three-phase cooperate together, restrain the inrush current when switching on, enhance the power factor of the power grid.

    Performance features:

    Rated voltage

       3-AC400V /AC690V50HZ   

    Insulation grade

       F

    Noise

       ≤70 d B

    Electric strength

       AC3000V 50Hz  5s  leakage current5m A

    Over current

       Allow Max power frequency: 105%, Max harmonic current flowing past reactor: 30%

    Ambient temperature

       -25~55℃  

    Operative norm

       GB10229-88 reactorIEC2891987 reactorJB9644-1999 reactor for transmission semiconductor    

    Dimensions and technical parameter:

    Voltage of system: 3-AC400V, reactance rate: 7%, allowable harmonic current flowing past reactor: 30%

    Adaptable voltage of capacitance:440V/450V/480V/525V

    Model of reactor(voltage of capacitance:450V)

    Figure  No.

    Adaptable power of capacitance (KVA)

    Power of reactor (KVA)

    Weight (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    CKSG-0.35-0.45-7-EISA

    A

    5

    0.35

    5.2

    150

    95

    160

    60

    67

    7*11

    CKSG-0.525-0.45-7-EISA

    7.5

    0.525

    5.3

    150

    95

    160

    60

    67

    7*11

    CKSG-0.7-0.45-7-EISA

    10

    0.7

    5.9

    180

    110

    190

    80

    67

    7*11

    CKSG-1.05-0.45-7-EISA

    15

    1.05

    8.6

    180

    130

    190

    80

    87

    7*11

    CKSG-1.4-0.45-7-EISA

    20

    1.4

    8.7

    180

    130

    190

    80

    87

    7*11

    CKSG-1.75-0.45-7-EISA

    25

    1.75

    9

    180

    130

    190

    80

    87

    7*11

    CKSG-2.1-0.45-7-EISA

    B

    30

    2.1

    11.2

    230

    140

    190

    110

    75

    9*18

    CKSG-2.8-0.45-7-EISA

    40

    2.8

    13

    230

    140

    220

    110

    75

    9*18

    CKSG-3.15-0.45-7-EISA

    45

    3.15

    13.6

    230

    140

    220

    110

    75

    9*18

    CKSG-3.5-0.45-7-EISA

    50

    3.5

    16.4

    260

    145

    230

    140

    85

    9*18

    CKSG-4.2-0.45-7-EISA

    60

    4.2

    17.5

    260

    145

    230

    140

    85

    9*18

    CKSG-5.6-0.45-7-EISA

    C

    80

    5.6

    22.1

    300

    160

    280

    170

    85

    11*18

    CKSG-6.3-0.45-7-EISA

    90

    6.3

    23.6

    300

    160

    280

    170

    85

    11*18

    CKSG-7.0-0.45-7-EISA

    100

    7

    24.8

    300

    160

    280

    170

    85

    11*18

    CKSG-8.4-0.45-7-EISA

    120

    8.4

    29.8

    300

    170

    280

    170

    95

    11*18

    Voltage of system: 3-AC400V, reactance rate: 14%,allowable harmonic current flowing past reactor: 30%.

    Adaptable voltage of capacitance:480V/525V

    Model of reactor(voltage of capacitance:450V)

    Figure  No.

    Adaptable power of capacitance (KVA)

    Power of reactor (KVA)

    Weight (KG)

    Dimensionsmm

    W

    D

    H

    W0

    D0

    A*B

    CKSG-0.7-0.48-14-EISA

    A

    5

    0.7

    5.8

    180

    110

    190

    80

    67

    7*11

    CKSG-1.05-0.48-14-EISA

    7.5

    1.05

    8.3

    180

    130

    190

    80

    87

    7*11

    CKSG-1.4-0.48-14-EISA

    10

    1.4

    8.6

    180

    130

    190

    80

    87

    7*11

    CKSG-2.1-0.48-14-EISA

    15

    2.1

    11.1

    230

    140

    220

    110

    75

    9*18

    CKSG-2.8-0.48-14-EISA

    20

    2.8

    12.9

    230

    140

    250

    110

    75

    9*18

    CKSG-3.5-0.48-14-EISA

    25

    3.5

    15.8

    260

    145

    260

    140

    85

    9*18

    CKSG-4.2-0.48-14-EISA

    30

    4.2

    16.4

    260

    145

    260

    140

    85

    9*18

    CKSG-5.6-0.48-14-EISA

    C

    40

    5.6

    25.3

    300

    170

    280

    170

    90

    11*18

    CKSG-6.3-0.48-14-EISA

    45

    6.3

    25.4

    300

    170

    280

    170

    90

    11*18

    CKSG-7.0-0.48-14-EISA

    50

    7

    25.5

    300

    170

    280

    170

    90

    11*18

    CKSG-8.4-0.48-14-EISA

    60

    8.4

    28.5

    300

    175

    280

    170

    95

    11*18

    CKSG-11.2-0.48-14-EISA

    80

    11.2

    37.5

    300

    190

    280

    170

    110

    11*18

    CKSG-12.6-0.48-14-EISA

    90

    12.6

    40.5

    300

    195

    280

    170

    115

    11*18

    CKSG-14.0-0.48-14-EISA

    100

    14

    45.4

    300

    205

    280

    170

    125

    11*18

    Remarks:Copper DC reactor(type EISC) will be a little heavier, the remaining items are the same