DC Balanced Reactor
    Variable Frequency Drive
    DC Flat Wave Reactor
    Input Reactor
    Output Reactor
    Energy Feedback Reactor
    Reactor of PMSM
    Rotor Inverter BOOST Reacto…
    Dv/dt Filter
    Sine Wave Filter
    Passive Harmonic Filter
    LCL Filter
    EMC Filter
    Power Quality
    SVG Reactor
    APF Reactor
    Three Phase Series Detuning…
    Three Phase Series Tuned Re…
    Single-phase series detunin…
    Electric Vehicle
    BOOST Reactor For EV
    PFC Reactor for Charger
    High Frequency Reactor
    High Frequency Transformer
    New Energy
    Wind Power Filter Reactor
    Photovoltaic Filter Reactor…
    Photovoltaic Isolation Tran…
    Transformer
    Rectifier Transformer
    Power Frequency Transformer…
    Energy Consumption Braking
    Braking Unit
    Wirewound Resistor
    Aluminum-enclosure Resistor…
    Braking Resistance Box
    Braking Resistance Cabinet

    Recommendation

    Current position:Home > Single-phase series detuning reactor > Single-phase Series Detuning Reactor

    Single-phase Series Detuning Reactor

    Comment     Time:2018-07-19    Views     Category:Single-phase series detuning reactor

    Circuitry application:

           There are lots of inductive load from power grid,which create inductive power  this reactor is in series with shunt capacitor, phase-splitting compensation, restrain the inrush current when switching on, enhance the power factor of the power grid..

    Performance features:

    Rated voltage

       3-AC400V/690V50HZ  

    Insulation grade

       F

    Noise

       ≤70 d B

    Electric strength

       AC3000V 50Hz  5s  leakage current5m A

    Over current

        Max power frequency: 105%, Max harmonic current flowing past capacitor: 30%

    Ambient temperature

       -25~55

    Operative norm

       GB10229-88 reactorIEC2891987 reactorJB9644-1999 reactor for transmission semiconductor


    Dimensions and technical parameter:

    Voltage of system: monophase AC220V, reactance rate: 7%,allowable harmonic current flowing past capacitor:60%

    Adaptable voltage of capacitance:250V/280V

    Model of reactor(voltage of capacitance:250V)

    Figure  No.

    Adaptable power of capacitance (KVA)

    Power of reactor (KVA)

    Weight  (KG)

    Dimensionsmm

    W

    D

    H

    W0

    D0

    A*B

    CKDG-0.35-0.25-7-EISA

    A

    5

    0.35

    4.8

    120

    105

    150

    70

    90

    7*14

    CKDG-0.525-0.25-7-EISA

    7.5

    0.525

    5.0

    120

    105

    150

    70

    90

    7*14

    CKDG-0.7-0.25-7-UISA

    B

    10

    0.7

    6.5

    160

    120

    190

    105

    65

    7*14

    CKDG-1.05-0.25-7-UISA

    15

    1.05

    6.8

    160

    120

    190

    105

    65

    7*14

    CKDG-1.4-0.25-7-UISA

    20

    1.4

    7.3

    160

    120

    190

    105

    65

    7*14

    CKDG-1.75-0.25-7-UISA

    25

    1.75

    8.8

    170

    140

    220

    115

    75

    7*14

    CKDG-2.1-0.25-7-UISA

    30

    2.1

    9.2

    170

    140

    220

    115

    75

    7*14

    CKDG-2.8-0.25-7-UISA

    40

    2.8

    10.4

    170

    140

    220

    115

    75

    7*14

    Voltage of system: monophase AC220V, reactance ratio: 14%,allowable harmonic current flowing past capacitor:30%

    Adaptable voltage of capacitance:280V

    Model of reactor(voltage of capacitance:280V)

    Figure  No.

    Adaptable power of capacitance(KVA)

    Power of reactor(KVA)

    Weight (KG)

    Dimensionsmm

    W

    D

    H

    W0

    D0

    A*B

    CKDG-0.7-0.28-14-UISA

    B

    5

    0.7

    7.0

    160

    120

    190

    105

    65

    7*14

    CKDG-1.05-0.28-14-UISA

    7.5

    1.05

    7.1

    160

    120

    190

    105

    65

    7*14

    CKDG-1.4-0.28-14-UISA

    10

    1.4

    7.6

    160

    120

    190

    105

    65

    7*14

    CKDG-2.1-0.28-14-UISA

    15

    2.1

    9.1

    170

    140

    220

    115

    75

    7*14

    CKDG-2.8-0.28-14-UISA

    20

    2.8

    10.4

    170

    140

    220

    115

    75

    7*14

    CKDG-3.5-0.28-14-UISA

    25

    3.5

    12.4

    170

    150

    220

    115

    85

    7*14

    CKDG-4.2-0.28-14-UISA

    30

    4.2

    14.5

    170

    160

    220

    115

    95

    7*14

    CKDG-5.6-0.28-14-UISA

    40

    5.6

    18.4

    170

      175

    220

    115

    110

    7*14

    Remarks:Copper DC reactor(type UISC) will be a little heavier, the remaining items are the same